دوره 7، شماره 2 - ( 2-1398 )                   جلد 7 شماره 2 صفحات 48-39 | برگشت به فهرست نسخه ها


XML English Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Asgharzadeh F, kermani M, Jonidi Jafari A, Taheri Otaghsara S S, Geraili Z. Air Born Bacteria Evaluation in The Kitchen Air of Restaurants in Babol City. Iran J Health Sci 2019; 7 (2) :39-48
URL: http://jhs.mazums.ac.ir/article-1-631-fa.html
Air Born Bacteria Evaluation in The Kitchen Air of Restaurants in Babol City. علوم بهداشتی ایران. 1398; 7 (2) :39-48

URL: http://jhs.mazums.ac.ir/article-1-631-fa.html


چکیده:   (2599 مشاهده)
Background and purpose: Bioaerosols enter into human body through various ways (inhalation, ingestion or skin absorption). The aim of this study was to investigate the type and density of the predominant bacteria in two seasons - cold and warm - in the kitchen air of restaurants.
Materials and Methods: This descriptive cross-sectional study was conducted on the air of restaurants' kitchen in Babol. Sampling was performed by using a personal sampling pump with impinger tank using a flow rate of 4 l/min during 50 minutes. Counting the colonies in the air was determined in terms of CFU/m3 and the type of grown bacteria was identified using different tests, such as Gram staining and biochemical methods. Temperature and humidity were recorded at the time of sampling, too. Totally, 120 samples of bacteria were taken from the indoor air of kitchens with and without air conditioning.
Results: The results showed that the highest and lowest densities of bacteria in cold season were 15 CFU/m3 and 63.7 CFU/m3, and in warm season, they were 19.6 CFU/m3 and 80 CFU/m3, respectively. The predominant bacteria were Gram-positive bacteria in the air of kitchen but Bacillus and Micrococcus were the most frequent.
Conclusion: The results showed that due to humidity and the temperature (warmer), bacterial density was higher in summer than winter. The concentration of bacteria in the kitchen and restaurant was also less than WHO recommendation and guide values ACGIH (up to 500 CFU/m3), respectively. So, air quality was found to be good and acceptable in terms of the restaurant kitchen.
متن کامل [PDF 574 kb]   (1392 دریافت)    
نوع مطالعه: پژوهشي | موضوع مقاله: مديريت خدمات بهداشتي و درماني

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2024 CC BY-NC 4.0 | Iranian Journal of Health Sciences

Designed & Developed by : Yektaweb